Research requirements of thoracic tissue forceps
Release time:
2022-08-26
Source:
Thoracic tissue forceps should be studied in at least the following aspects. Thoracic tissue forceps performance study provides product performance study data and product technical requirements study preparation instructions, including the basis for determining effectiveness, safety indicators and other indicators related to quality control, standards or methods used, reasons for use and theoretical basis. For new materials used in medical devices, it is necessary to provide relevant research data on the applicability of materials. When the biocompatibility evaluation of thoracic tissue forceps is registered, the product should be evaluated according to the nature of the material used and the degree of contact with human beings according to the standard. At a minimum, cytotoxicity, intradermal reactions and
thoracic tissue forcepsResearch requirements
Thoracic tissue forceps should be studied in at least the following aspects. Thoracic tissue forceps performance study provides product performance study data and product technical requirements study preparation instructions, including the basis for determining effectiveness, safety indicators and other indicators related to quality control, standards or methods used, reasons for use and theoretical basis. For new materials used in medical devices, it is necessary to provide relevant research data on the applicability of materials. When the biocompatibility evaluation of thoracic tissue forceps is registered, the product should be evaluated according to the nature of the material used and the degree of contact with human beings according to the standard. At a minimum, biological evaluation tests for cytotoxicity, intradermal reactions, and sensitization should be performed.

The research on the sterilization/disinfection process of disposable live harvesting forceps suggests that surgeons who have just used the ultrasonic cutting hemostatic knife system should receive preoperative training and arrange relevant nurses to pay attention to the doctor's surgical habits and give timely feedback. Make a special use record table, register the use time, operation name, user, relevant circuit nurse and hand washing nurse, tool head model and product batch number, tool head use times, host use times and status. These data can clearly reflect the doctor's usage habits and maintenance of the ultrasonic knife, and provide reference materials for equipment management; Provide multi-head rotation to ensure smooth clinical use; Other maintenance work related to the ultrasonic cutting hemostatic knife system should be carried out according to the following steps. When testing and using the ultrasonic cutting hemostatic knife system, do not allow the metal cutter head to touch metal objects. When the ultrasonic knife is not clamped, keep the jaw of the knife head open, do not close the jaw for air excitation, so as not to damage the tissue pad on the knife head. Try not to use the ultrasonic knife in the blood pool, and the continuous excitation time should not exceed 7s each time, so as not to damage the life of the cutter head. After every 15-20 minutes of work, the instrument nurse of the ultrasonic cutting hemostatic knife system is responsible for cleaning and maintaining the knife head. Be careful not to let the tip of the knife touch the metal basin wall when repairing. When not in use for a long time during operation, please switch the host to the standby state to prevent the cutter head from contacting the human body and hard objects. The blade of the ultrasonic knife is exquisite and expensive. Handle with care to avoid falls and impacts. In particular, the handle of the ultrasonic knife contains fragile key parts, which need to be protected. The instrument nurse should be familiar with the installation and removal methods of the ultrasonic cutting hemostatic knife system. After operation, remove the tool head and handle, clean it in time, soak it with enzyme for 15 minutes and then clean it. The method was the same as the intraoperative maintenance. Be careful not to scrape, grind or brush the tool head with force.
In order to prevent damage to the head tissue pad of the ultrasonic cutting hemostatic knife system and affect the power and service life, please use a soft cloth to clean and dry or blow dry. The cavity can be flushed with a high-pressure water gun or needle to remove tissue fragments and blood, and then dried. If possible, it can be dried in a warm box. Clarify the sterilization process (methods and parameters) and sterility assurance level, and provide sterilization confirmation report. and provide a residual toxicity study report. Sterilization methods such as ethylene oxide sterilization and other easy to produce residues, should be clear about the residue and treatment methods, and provide research data.thoracic tissue forcepsShelf Life and Packaging Studies Shelf life validation of thoracic tissue forceps products can be performed using real-time aging or accelerated aging studies. Real-time aging research is a method that can reflect the actual stability requirements of the product under the specified storage conditions, and should follow the principle of overload test.
Related News