How does ultrasonic soft tissue cutting hemostatic surgical equipment maintain?


The ultrasonic soft tissue cutting hemostasis surgical equipment is designed to use different ultrasonic energy to cut the soft tissue and complete hemostasis and/or coagulation during surgical treatment. The ultrasonic soft tissue cutting hemostasis surgical equipment is suitable for soft tissue incisions that need to control bleeding and thermal damage, and can close blood vessels with a diameter of less than 3mm. The product has been unsuitable for bone resection, tubal ligation, and nerve passage surgery.

  Ultrasonic soft tissue cutting hemostatic surgical equipmentDesigned to use different ultrasonic energy to cut soft tissue and complete hemostasis and/or coagulation during surgical treatment. This product is suitable for soft tissue incisions that need to control bleeding and thermal damage, and can close blood vessels with a diameter of less than 3mm. The product has been unsuitable for bone resection, tubal ligation, and nerve passage surgery.


Ultrasonic soft tissue cutting hemostasis surgical equipment converts electrical energy into ultrasonic mechanical energy through the handle, so that the knife head is in contact with the tissue protein at high frequency and high amplitude, resulting in cavitation, so that the water in the tissue evaporates rapidly, the hydrogen bond of the protein is destroyed, and the denaturation becomes viscous The blood clot can be cut, coagulated and stopped bleeding.

       超声软组织切割止血手术设备

Ultrasonic soft tissue cutting hemostatic surgical equipment is a kind of ultrasonic that uses the principle of ultrasonic wave and can cut the internal tissues of the human body like a real knife. It uses the strong penetrating power of ultrasonic waves, through hundreds of beams of high-energy ultrasonic waves emitted, to focus on tumor tissues like concentrated solar energy, and uses high-energy ultrasonic cavitation to rupture the cell membrane of tumor tissues. At the same time, high-energy ultrasonic waves release huge energy and quickly convert it into heat energy. The temperature of tumor tissues at the instant focus reaches 70 ℃-100 ℃.


Ultrasonic soft tissue cutting hemostatic surgical equipment is a new type of surgical instrument, which has been used in clinical surgery since the late 1980 s. The scientific name of the "ultrasonic knife" is high-intensity focused ultrasound. We may not be unfamiliar with the application of ultrasound in the medical field. For example, many hospitals in China are equipped with B- ultrasound. B ultrasound is a diagnostic equipment, using low-intensity ultrasound.


How to maintain ultrasonic soft tissue cutting hemostatic surgical equipment? Let's take a look


1. The host of the ultrasonic scalpel should be inserted into the special power outlet, and the test should be started after pressing the STANDBY. During the test, the cutter head should be in the air and the jaw should be opened. The test can be operated by foot control or manual control. The whole test process must be achieved. The test head should be opened, not closed, not stepped on, and not encountered metal. Otherwise the test will be repeated.


2. Continuous work for more than 10 seconds will cause great damage to the cutter head. Generally, it will be broken in 7 seconds. Try to let go and develop the cutter head again. When using, try to operate the front 2/3 of the tissue collet. When using, step on your feet every 10-15 minutes to stop your head in the water, shake gently, rinse the head tissue and blood to avoid blockage.


3. Do not agree to rotate the knife head at work, otherwise the knife head will be seriously damaged, and the bite tissue cannot be picked in the direction, prompting the doctor to tighten the tissue to ensure a certain tension.


  4、Ultrasonic soft tissue cutting hemostatic surgical equipmentPress the STANDBY key after use, and close the main machine after 5 minutes. The cutter head should be cleaned immediately after use. When cleaning the 10mm cutter core, gently wipe off some residue and condensate on the surface of the cutter head with a soft cloth. Do not use a brush to scrub, so as not to cause damage and affect the social function of the silicone ring. Immerse the suitable enzyme solution and keep it by soaking, cleaning and drying.